Overall Rating | Platinum |
---|---|
Overall Score | 91.10 |
Liaison | Alex Davis |
Submission Date | Feb. 28, 2023 |
Arizona State University
OP-1: Emissions Inventory and Disclosure
Status | Score | Responsible Party |
---|---|---|
3.00 / 3.00 |
Jenae
Camacho Sustainability Analyst University Sustainability Practices |
"---"
indicates that no data was submitted for this field
Part 1. Greenhouse gas emissions inventory
Yes
A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:
SIMAP
Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
Yes
A brief description of the GHG inventory verification process:
The annual GHG inventory is third-party verified by SIMAP. This data is also reviewed twice during the inventory by a committee of ASU's sustainability operations leadership to ensure that the data represents an accurate and complete inventory of ASU's GHG emissions. During this process, data sources, notable year to year changes, and potential missing information is addressed.
Documentation to support the GHG inventory verification process:
Scope 1 GHG emissions
Weight in MTCO2e | |
Stationary combustion | 62,441 Metric tons of CO2 equivalent |
Other sources (mobile combustion, process emissions, fugitive emissions) | 9,909.30 Metric tons of CO2 equivalent |
Total gross Scope 1 GHG emissions, performance year:
72,350.30
Metric tons of CO2 equivalent
Scope 2 GHG emissions
Weight in MTCO2e | |
Imported electricity | 0 Metric tons of CO2 equivalent |
Imported thermal energy | 4,241 Metric tons of CO2 equivalent |
Total gross Scope 2 GHG emissions, performance year:
4,241
Metric tons of CO2 equivalent
GHG emissions from biomass combustion
0
Metric tons of CO2 equivalent
Scope 3 GHG emissions
Yes or No | Weight in MTCO2e | |
Business travel | Yes | 4,131 Metric tons of CO2 equivalent |
Commuting | Yes | 19,448.20 Metric tons of CO2 equivalent |
Purchased goods and services | Yes | 276 Metric tons of CO2 equivalent |
Capital goods | No | 0 Metric tons of CO2 equivalent |
Fuel- and energy-related activities not included in Scope 1 or Scope 2 | Yes | 5,375 Metric tons of CO2 equivalent |
Waste generated in operations | Yes | 2,080 Metric tons of CO2 equivalent |
Other sources | Yes | 944 Metric tons of CO2 equivalent |
Total Scope 3 GHG emissions, performance year:
32,254.20
Metric tons of CO2 equivalent
A brief description of how the institution accounted for its Scope 3 emissions:
Calculated using SIMAP tool.
Other sources represents wastewater and study abroad air travel.
Other sources represents wastewater and study abroad air travel.
Part 2. Air pollutant emissions inventory
Yes
Annual weight of emissions for::
Weight of Emissions | |
Nitrogen oxides (NOx) | 64.63 Tons |
Sulfur oxides (SOx) | 12.21 Tons |
Carbon monoxide (CO) | 10.54 Tons |
Particulate matter (PM) | 14.78 Tons |
Ozone (O3) | 0 Tons |
Lead (Pb) | 0 Tons |
Hazardous air pollutants (HAPs) | 0 Tons |
Ozone-depleting compounds (ODCs) | 0 Tons |
Other standard categories of air emissions identified in permits and/or regulations | 2.32 Tons |
Do the air pollutant emissions figures provided include the following sources?:
Yes or No | |
Major stationary sources | No |
Area sources | Yes |
Mobile sources | No |
Commuting | Yes |
Off-site electricity production | Yes |
None
A brief description of the methodology(ies) the institution used to complete its air emissions inventory:
Multiple, detailed in attached "Additional documentation to support the submission":
Area sources from campus generation
Commuting based on survey data and AFLEET emissions factors
Off-site electricity consumption based on eGrid 2021 data
Ozone, Lead, HAPs, and ODCs are not tracked through our reporting.
Area sources from campus generation
Commuting based on survey data and AFLEET emissions factors
Off-site electricity consumption based on eGrid 2021 data
Ozone, Lead, HAPs, and ODCs are not tracked through our reporting.
Optional Fields
---
Gross Scope 2 GHG emissions from imported thermal energy (location-based) :
---
Website URL where information about the institution’s emissions inventories is available:
---
Additional documentation to support the submission:
Data source(s) and notes about the submission:
---
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.