Overall Rating Silver
Overall Score 64.13
Liaison Michael Kensler
Submission Date Feb. 4, 2022

STARS v2.2

Auburn University
OP-3: Building Design and Construction

Status Score Responsible Party
Complete 1.45 / 3.00 Richard Guether
Director
Campus Planning & Space Management
"---" indicates that no data was submitted for this field

Total floor area of newly constructed or renovated building space:
80,535.94 Square meters

Floor area of eligible building space designed and built in accordance with published green building codes, policies, and/or rating systems:
Floor area
Certified at the highest achievable level under a multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Platinum or Certified Living Building) 0 Square meters
Certified at the 2nd highest level under a 4- or 5-tier, multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Gold) 9,235.77 Square meters
Certified at mid-level under a 3- or 5-tier, multi-attribute GBC rating system for design and construction (e.g., BREEAM Very Good) 0 Square meters
Certified at a step above minimum level under ar 4- or 5-tier, multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Silver) 13,804 Square meters
Certified at minimum level under a multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Certified) 4,043.79 Square meters
Certified/verified at any level under a multi-attribute, non-GBC rating system for design and construction, a green building code, or a single-attribute rating system for design and construction 0 Square meters
Designed and built in accordance with a multi-attribute green building code, policy, guideline, or rating system, but not certified/verified 48,174.66 Square meters
Designed and built in accordance with a single-attribute green building code, policy, guideline, or rating system, but not certified/verified 0 Square meters
Total 75,258.21 Square meters

Percentage of newly constructed or renovated building space certified under a green building rating system for design and construction:
33.63

A list of new construction and major renovation projects that indicates the green building code, policy/guideline, or rating system that applies to each building:
---

An inventory of new construction and major renovation projects that indicates the green building code, policy/guideline, or rating system that applies to each building:

Optional Fields 

Website URL where information about the institution’s green building design and construction program is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
From 2013 to 2017, an Alabama Executive Order precluded state agencies from using appropriations to pursue LEED certification. As such, the Facilities Management and Office of Sustainability staff worked together to take all major LEED-design parameters and incorporate them into the university's design and construction standards during that time period. Staff from both offices can attest that all buildings initiated during that time frame and listed on the spreadsheet as using AU Design Standards included sustainability elements from all major LEED categories. Once the executive order ban was lifted, the university quickly moved to require all new buildings be built to a minimum of LEED Silver. The specific document listing out the design standards used during the 2013-2017 time has since been revised and replaced given this change, so we're unable to provide a direct link to the old standards at this time.

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.