Overall Rating | Silver |
---|---|
Overall Score | 53.49 |
Liaison | Julia Angstmann |
Submission Date | Dec. 20, 2021 |
Butler University
OP-2: Greenhouse Gas Emissions
Status | Score | Responsible Party |
---|---|---|
2.94 / 8.00 |
Taylor
Korn Campus Engineer University Operations |
"---"
indicates that no data was submitted for this field
Scope 1 and Scope 2 GHG emissions
Gross GHG emissions
Performance year | Baseline year | |
Gross Scope 1 GHG emissions from stationary combustion | 7,654 Metric tons of CO2 equivalent | 5,840 Metric tons of CO2 equivalent |
Gross Scope 1 GHG emissions from other sources | 284 Metric tons of CO2 equivalent | 266 Metric tons of CO2 equivalent |
Gross Scope 2 GHG emissions from imported electricity | 25,904 Metric tons of CO2 equivalent | 28,333 Metric tons of CO2 equivalent |
Gross Scope 2 GHG emissions from imported thermal energy | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Total | 33,842 Metric tons of CO2 equivalent | 34,439 Metric tons of CO2 equivalent |
Carbon sinks
Performance year | Baseline year | |
Third-party verified carbon offsets purchased | 0 Metric tons of CO2 equivalent | 205 Metric tons of CO2 equivalent |
Institution-catalyzed carbon offsets generated | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from on-site composting | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from non-additional sequestration | 0 Metric tons of CO2 equivalent | --- |
Carbon sold or transferred | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Net carbon sinks | 0 Metric tons of CO2 equivalent | 205 Metric tons of CO2 equivalent |
If total performance year carbon sinks are greater than zero, provide:
N/A
Adjusted net GHG emissions
Performance year | Baseline year | |
Adjusted net GHG emissions | 33,842 Metric tons of CO2 equivalent | 34,234 Metric tons of CO2 equivalent |
Performance and baseline periods
Performance year | Baseline year | |
Start date | June 1, 2020 | June 1, 2015 |
End date | May 31, 2021 | May 31, 2016 |
A brief description of when and why the GHG emissions baseline was adopted:
The baseline was adopted because we track GHG by fiscal year.
Part 1. Reduction in GHG emissions per person
Weighted campus users
Performance year | Baseline year | |
Number of students resident on-site | 2,903 | 2,045 |
Number of employees resident on-site | 11 | 7 |
Number of other individuals resident on-site | 15 | 17 |
Total full-time equivalent student enrollment | 5,828 | 4,156 |
Full-time equivalent of employees | 1,069 | 1,144 |
Full-time equivalent of students enrolled exclusively in distance education | 98 | 0 |
Weighted Campus Users | 5,842.75 | 4,505 |
Metrics used in scoring for Part 1
Performance year | Baseline year | |
Adjusted net Scope 1 and 2 GHG emissions per weighted campus user | 5.79 Metric tons of CO2 equivalent | 7.60 Metric tons of CO2 equivalent |
Percentage reduction in adjusted net Scope 1 and Scope 2 GHG emissions per weighted campus user from baseline:
23.78
Part 2. GHG emissions per unit of floor area
Performance year floor area
289,996.71
Gross square meters
Floor area of energy intensive building space, performance year:
Floor area | |
Laboratory space | 6,541.21 Square meters |
Healthcare space | 0 Square meters |
Other energy intensive space | 9,004.81 Square meters |
EUI-adjusted floor area, performance year:
312,083.94
Gross square meters
Metric used in scoring for Part 2
0.11
MtCO2e per square meter
A brief description of the institution’s GHG emissions reduction initiatives:
The Butler University Sustainability and Climate Action Plan (BUSCA) includes GHG reduction initiatives.
Website URL where information about the institution's GHG emissions is available:
Additional documentation to support the submission:
---
Data source(s) and notes about the submission:
Butler used the most recent fiscal year, 2020-2021, data in OP2 which is why the data is different from the 2019 GHG calculations in OP1.
For OP1, Butler used our last GHG report which was analyzed in 2019 with 2018-2019 data (vs 2020-2021 data in OP2). Butler is a signatory of Second Nature President's Carbon Commitment and analyzes our scope 1, 2 and partial 3 GHG every 3 years in accordance with this commitment.
For OP1, Butler used our last GHG report which was analyzed in 2019 with 2018-2019 data (vs 2020-2021 data in OP2). Butler is a signatory of Second Nature President's Carbon Commitment and analyzes our scope 1, 2 and partial 3 GHG every 3 years in accordance with this commitment.
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.