OP-5: Building Energy Efficiency

Status Score Responsible Party
Complete 4.57 / 6.00 Gregory Wiggins
Climate & Energy Analyst
Facilities Management & Services
"---" indicates that no data was submitted for this field

Part 1. Site energy use per unit of floor area

Performance year energy consumption

Electricity use, performance year (report kilowatt-hours):
kWh MMBtu
Imported electricity 21,581,607 Kilowatt-hours 73,636.44 MMBtu
Electricity from on-site, non-combustion facilities/devices (e.g., renewable energy systems) 41,156 Kilowatt-hours 140.42 MMBtu

Stationary fuels and thermal energy, performance year (report MMBtu):
MMBtu
Stationary fuels used on-site to generate electricity and/or thermal energy 107,675.90 MMBtu
Imported steam, hot water, and/or chilled water 0 MMBtu

Total site energy consumption, performance year:
181,452.77 MMBtu

Performance year building space

Gross floor area of building space, performance year:
304,153.46 Gross square meters

Floor area of energy intensive space, performance year:
Floor area
Laboratory space 8,169.33 Square meters
Healthcare space 1,208.95 Square meters
Other energy intensive space 10,463.48 Square meters

EUI-adjusted floor area, performance year:
333,373.50 Gross square meters

Performance year heating and cooling degree days 

Degree days, performance year:
Degree days
Heating degree days 1,652.39 Degree-Days (°C)
Cooling degree days 1,384.17 Degree-Days (°C)

Total degree days, performance year:
3,036.56 Degree-Days (°C)

Performance period

Start and end dates of the performance year (or 3-year period):
Start date End date
Performance period July 1, 2020 June 30, 2021

Metric used in scoring for Part 1

Total site energy consumption per unit of EUI-adjusted floor area per degree day, performance year:
55.32 Btu / GSM / Degree-Day (°C)

Part 2. Reduction in source energy use per unit of floor area

Baseline year energy consumption

STARS 2.2 requires electricity data in kilowatt-hours (kWh). If a baseline has already been established in a previous version of STARS and the institution wishes to continue using it, the electricity data must be re-entered in kWh. To convert existing electricity figures from MMBtu to kWh, simply multiply by 293.07107 MMBtu/kWh.

Electricity use, baseline year (report kWh):
kWh MMBtu
Imported electricity 28,582,609.37 Kilowatt-hours 97,523.86 MMBtu
Electricity from on-site, non-combustion facilities/devices (e.g., renewable energy systems) 314,993 Kilowatt-hours 1,074.76 MMBtu

Stationary fuels and thermal energy, baseline year (report MMBtu):
MMBtu
Stationary fuels used on-site to generate electricity and/or thermal energy 117,602 MMBtu
Imported steam, hot water, and/or chilled water 0 MMBtu

Total site energy consumption, baseline year:
216,200.62 MMBtu

Baseline year building space

Gross floor area of building space, baseline year:
271,771.19 Gross square meters

Baseline period

Start and end dates of the baseline year (or 3-year period):
Start date End date
Baseline period July 1, 2017 June 30, 2018

A brief description of when and why the energy consumption baseline was adopted:
---

Source energy

Source-site ratio for imported electricity:
3

Total energy consumption per unit of floor area:
Site energy Source energy
Performance year 0.60 MMBtu per square meter 1.08 MMBtu per square meter
Baseline year 0.80 MMBtu per square meter 1.51 MMBtu per square meter

Metric used in scoring for Part 2

Percentage reduction in total source energy consumption per unit of floor area from baseline:
28.58

Optional Fields 

Documentation to support the performance year energy consumption figures reported above:
---

A brief description of the institution's initiatives to shift individual attitudes and practices in regard to energy efficiency:
---

A brief description of energy use standards and controls employed by the institution:
Through the campus EMS system, as well as a campus wide scheduling program for classes and events, the central plant references this information to determine when building temperatures are allowed to go outside the posted range. This also allows operators to curtail building fans to reduce power consumption.

A brief description of Light Emitting Diode (LED) lighting and other energy-efficient lighting strategies employed by the institution:
CSU Chico is deploying a multitude of buildings with retrofitted LED light fixtures. Major projects include the Mell Memorial Union and Laxson Auditorium buildings. The estimated reduction of interior light energy demand is projected to be 50% of the current light fixtures.

Projects for further LED installation campus-wide are constantly being phased into new projects.

A brief description of passive solar heating, geothermal systems, and related strategies employed by the institution:
N/A

A brief description of co-generation employed by the institution:
N/A

A brief description of the institution's initiatives to replace energy-consuming appliances, equipment, and systems with high efficiency alternatives:
N/A

Website URL where information about the institution’s energy conservation and efficiency program is available:
Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
Degree days acquired through https://www.degreedays.net/#generate

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.