Overall Rating | Silver - expired |
---|---|
Overall Score | 55.87 |
Liaison | Ian Johnson |
Submission Date | July 29, 2014 |
Executive Letter | Download |
Colorado College
OP-1: Greenhouse Gas Emissions
Status | Score | Responsible Party |
---|---|---|
5.62 / 10.00 |
Michael
Brubaker Campus Operations & Plant Manger Facilities Services |
"---"
indicates that no data was submitted for this field
None
Does the institution's GHG emissions inventory include all Scope 1 and Scope 2 GHG emissions?:
Yes
None
Does the institution's GHG emissions inventory include all Scope 3 GHG emissions from any of the following categories?:
Yes or No | |
Business travel | Yes |
Commuting | Yes |
Purchased goods and services | No |
Capital goods | No |
Fuel- and energy-related activities not included in Scope 1 or Scope 2 | Yes |
Waste generated in operations | Yes |
None
Does the institution's GHG emissions inventory include Scope 3 emissions from other categories?:
No
None
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:
To complete the GHG emissions inventory, Colorado College utilized the Clean Air-Cool Planet (CAPC) as its emissions calculation tool. CACP is based on well-reviewed methodologies from the Intergovernmental Panel on Climate Change. The tool provides an accessible and well-documented platform for maintaining the greenhouse gas inventory. It is targeted specifically at colleges and universities, allowing for easy comparison with other institutions.
None
Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
No
None
A brief description of the internal and/or external verification process:
---
None
Scope 1 and Scope 2 GHG emissions::
Performance Year | Baseline Year | |
Scope 1 GHG emissions from stationary combustion | 6,008 Metric tons of CO2 equivalent | 7,318 Metric tons of CO2 equivalent |
Scope 1 GHG emissions from other sources | 294 Metric tons of CO2 equivalent | 452 Metric tons of CO2 equivalent |
Scope 2 GHG emissions from purchased electricity | 7,997 Metric tons of CO2 equivalent | 13,380 Metric tons of CO2 equivalent |
Scope 2 GHG emissions from other sources | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
None
Figures needed to determine total carbon offsets::
Performance Year | Baseline Year | |
Institution-catalyzed carbon offsets generated | 390 Metric tons of CO2 equivalent | 11.80 Metric tons of CO2 equivalent |
Carbon sequestration due to land that the institution manages specifically for sequestration | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from on-site composting | 70 Metric tons of CO2 equivalent | 12 Metric tons of CO2 equivalent |
Third-party verified carbon offsets purchased | 33 Metric tons of CO2 equivalent | 39 Metric tons of CO2 equivalent |
None
A brief description of the institution-catalyzed carbon offsets program:
CC offsets carbon emissions through its four solar installations on campus. The College invested in its first solar project during the 2007/2008 fiscal years, installing panels onto the Edith Gaylord roof (39,600 kWh). During 2011/2012, it purchased panels for the Worner Center (63,000 kWh) and in 2012/2013 for KRCC (3,240 kWh) and the Children's Center (25,200 kWh).
In addition, the institution generates offsets through its Energy Audit and Retrofit Program. The program offers students enrolled in the "Energy" (EV 212) course an opportunity to learn the science and mechanics behind energy audits and retrofits through hands-on practice and community-based service. After conducting the audit and obtaining an air exchange value, students work to improve the building's efficiency by installing additional insulation. The project targets low-income neighborhoods and typically results in one completed house per year. However, even though the program has reduced emissions, there is not sufficient data to include these offsets in the number for "institution-catalyzed carbon offsets generated".
None
A brief description of the carbon sequestration program and reporting protocol used:
---
None
A brief description of the composting and carbon storage program:
In 2011, Colorado College added commercial composting to its solid waste services. The program accommodates all pre- and post consumer food waste from dining & catering and paper towel waste from campus bathrooms. Compost waste is handled through CC's facilities management contractor Sodexo and is hulled from the college to a waste management site via a local company Bestway Disposal.
None
A brief description of the purchased carbon offsets, including third party verifier(s) and contract timeframes:
In November 2012, the College purchased 230 kW of solar panels in SunShare's solar garden project. As part of this purchase, the College receives all energy produced by the panels for the next twenty years and renewable energy certificates from SunShare each year. For the 2013 academic year these certificates totaled 462 MWh's.
Beginning in 2012, CC has purchased blocks of green power from Colorado Springs Utilities on a monthly basis. The wind power is generated from the Ponnequin Wind Facility, located along the Colorado-Wyoming border. One block is equal to 100-kilowatt hours of electricity. Colorado College has purchased enough blocks to generate 2,000,000 kWh. REC's have been verified through Green-e, an independent certification program.
None
Figures needed to determine “Weighted Campus Users”::
Performance Year | Baseline Year | |
Number of residential students | 1,530 | 1,480 |
Number of residential employees | 19 | 28 |
Number of in-patient hospital beds | 0 | 0 |
Full-time equivalent enrollment | 2,034 | 1,996.50 |
Full-time equivalent of employees | 625 | 685 |
Full-time equivalent of distance education students | 0 | 0 |
None
Start and end dates of the performance year and baseline year (or three-year periods):
Start Date | End Date | |
Performance Year | July 1, 2011 | June 30, 2012 |
Baseline Year | July 1, 2005 | June 30, 2006 |
None
A brief description of when and why the GHG emissions baseline was adopted:
---
None
Gross floor area of building space, performance year:
1,910,462
Square feet
None
Floor area of energy intensive building space, performance year:
Floor Area | |
Laboratory space | 195,825 Square feet |
Healthcare space | 0 Square feet |
Other energy intensive space | 52,584 Square feet |
None
Scope 3 GHG emissions, performance year::
Emissions | |
Business travel | 3,794 Metric tons of CO2 equivalent |
Commuting | 560 Metric tons of CO2 equivalent |
Purchased goods and services | --- |
Capital goods | --- |
Fuel- and energy-related activities not included in Scope 1 or Scope 2 | 790 Metric tons of CO2 equivalent |
Waste generated in operations | 2,114 Metric tons of CO2 equivalent |
Other categories (please specify below) | --- |
None
A brief description of the sources included in Scope 3 GHG emissions from "other categories":
---
None
A copy of the most recent GHG emissions inventory:
---
None
The website URL where the GHG emissions inventory is posted:
None
A brief description of the institution’s GHG emissions reduction initiatives, including efforts made during the previous three years:
Colorado College is committed to meeting its 2020 carbon neutrality goal. In the first four years, as directed by the Sustainability Plan drafted in 2009, Colorado College reduced carbon emissions by more than 20% and saved $1.74 million in utility costs. Utilities management at Colorado College has become an area of increased emphasis. In FY13 CC experienced continued success in decreasing energy use and costs campus-wide. Cumulative avoided costs for utilities are estimated in excess of $2.1M since the 2008 baseline. Recent and notable accomplishments include: hiring of a full-time on Campus Energy Manager; developing the Carbon Neutrality Plan through collaboration between the Office of Sustainability, Facilities Services, and the Campus Sustainability Council; increasing renewable energy purchases via wind from Colorado Springs Utilities and solar from SunShare; and introducing Sofame Heat Recovery at the Central Heating Plant.
Data source(s) and notes about the submission:
CC Carbon Neutrality Plan: http://rs.acupcc.org/site_media/uploads/cap/1155-cap.pdf
The greenhouse gas inventory includes Colorado College's main campus, the Florissant CC Cabin, and the Baca Campus at Crestone, Colorado. Properties owned by the College but managed by external entities were excluded from the inventory, because the College is not responsible for the occupancy or maintenance of utilities for the associated buildings.
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.