Overall Rating Gold - expired
Overall Score 68.19
Liaison Ian Johnson
Submission Date July 14, 2017
Executive Letter Download

STARS v2.1

Colorado College
OP-1: Greenhouse Gas Emissions

Status Score Responsible Party
Complete 5.95 / 10.00 Ian Johnson
Sustainability Director
Office of Sustainability
"---" indicates that no data was submitted for this field

Part 1 

Has the institution conducted a GHG emissions inventory that includes all Scope 1 and 2 emissions? :
Yes

Does the institution’s GHG emissions inventory include all, some or none of its Scope 3 GHG emissions from the following categories?:
All, Some, or None
Business travel All
Commuting All
Purchased goods and services None
Capital goods None
Waste generated in operations All
Fuel- and energy-related activities not included in Scope 1 or Scope 2 All
Other categories None

A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory, including how the institution accounted for each category of Scope 3 emissions reported above:
To complete the GHG emissions inventory, Colorado College utilized the Clean Air-Cool Planet (CAPC) as its emissions calculation tool. CACP is based on well-reviewed methodologies from the Intergovernmental Panel on Climate Change. The tool provides an accessible and well-documented platform for maintaining the greenhouse gas inventory. It is targeted specifically at colleges and universities, allowing for easy comparison with other institutions.

Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
Yes

A brief description of the internal and/or external verification process:
The GHG inventory is conducted by a lead GHG Inventory intern and volunteer team members (students) who work for the Office of Sustainability. The Sustainability Director maintains a Greenhouse Gas Inventory Quantifier certification through CSA Group (CSA Groups is the third-party oversight to ISO Standard 14064/5 that deals with quantification of greenhouse gases). The Sustainability Director reviews and validates the information collected and submitted by the Greenhouse Gas Inventory Team.

Documentation to support the internal and/or external verification process:
---

Does the institution wish to pursue Part 2 and Part 3 of this credit? (reductions in Scope 1 and Scope 2 GHG emissions):
Yes

Part 2 

Gross Scope 1 and Scope 2 GHG emissions:
Performance Year Baseline Year
Gross Scope 1 GHG emissions from stationary combustion 5,751.13 Metric tons of CO2 equivalent 9,832.98 Metric tons of CO2 equivalent
Gross Scope 1 GHG emissions from other sources 463.74 Metric tons of CO2 equivalent 311.72 Metric tons of CO2 equivalent
Gross Scope 2 GHG emissions from purchased electricity 12,447.70 Metric tons of CO2 equivalent 15,742.03 Metric tons of CO2 equivalent
Gross Scope 2 GHG emissions from other sources 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Total 18,662.57 Metric tons of CO2 equivalent 25,886.73 Metric tons of CO2 equivalent

Start and end dates of the performance year and baseline year (or three-year periods):
Start Date End Date
Performance Year July 1, 2015 June 30, 2016
Baseline Year July 1, 2007 June 30, 2008

A brief description of when and why the GHG emissions baseline was adopted (e.g. in sustainability plans and policies or in the context of other reporting obligations):
---

Figures needed to determine total carbon offsets:
Performance Year Baseline Year
Third-party verified carbon offsets purchased (exclude purchased RECs/GOs) 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Institution-catalyzed carbon offsets generated 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon sequestration due to land that the institution manages specifically for sequestration 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon storage from on-site composting 0 Metric tons of CO2 equivalent 12 Metric tons of CO2 equivalent
Carbon offsets included above for which the emissions reductions have been sold or transferred by the institution 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Net carbon offsets 0 Metric tons of CO2 equivalent 12 Metric tons of CO2 equivalent

If total performance year carbon offsets are greater than zero, provide:

A brief description of the offsets in each category reported above, including vendor, project source, verification program and contract timeframes (as applicable):
---

The reporting fields in the table below are reserved for institutions that have NOT already accounted for renewable energy purchases (including RECs and GOs) in their Scope 2 GHG emissions calculations. Other institutions - including all SIMAP users - should report zero ('0') to avoid double-counting. 

Emissions reductions attributable to Renewable Energy Certificate (REC) or Guarantee of Origin (GO) purchases:
Performance Year Baseline Year
Emissions reductions attributable to REC/GO purchases 933.19 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

A brief description of the purchased RECs/GOs including vendor, project source and verification program:
Colorado College has 1/4 share of the two solar gardens located in Colorado Springs, CO: Clean Energy Collective and SunShare. Colorado College receives bill credits from the project developers as well as renewable energy credits verified through Green-e

Adjusted net Scope 1 and 2 GHG emissions:
Performance Year Baseline Year
Adjusted net Scope 1 and 2 GHG emissions 17,729.38 Metric tons of CO2 equivalent 25,874.73 Metric tons of CO2 equivalent

Figures needed to determine “Weighted Campus Users”:
Performance Year Baseline Year
Number of students resident on-site 1,561 1,480
Number of employees resident on-site 7 28
Number of other individuals resident on-site and/or staffed hospital beds 0 0
Total full-time equivalent student enrollment 2,277 1,996.50
Full-time equivalent of employees (staff + faculty) 782 685
Full-time equivalent of students enrolled exclusively in distance education 0 0
Weighted campus users 2,686.25 2,388.13

Adjusted net Scope 1 and 2 GHG emissions per weighted campus user:
Performance Year Baseline Year
Adjusted net Scope 1 and 2 GHG emissions per weighted campus user 6.60 Metric tons of CO2 equivalent 10.83 Metric tons of CO2 equivalent

Percentage reduction in adjusted net Scope 1 and Scope 2 GHG emissions per weighted campus user from baseline:
39.08

Part 3

Gross floor area of building space, performance year:
2,034,519 Gross square feet

Floor area of energy intensive building space, performance year:
Floor Area
Laboratory space 195,825 Square feet
Healthcare space 0 Square feet
Other energy intensive space 32,584 Square feet

EUI-adjusted floor area, performance year:
26,465,797.03 Gross square feet

Adjusted net Scope 1 and 2 GHG emissions per unit of EUI-adjusted floor area, performance year:
0 MtCO2e per square foot

Optional Fields 

Scope 3 GHG emissions, performance year:
Emissions
Business travel 4,694.19 Metric tons of CO2 equivalent
Commuting 2,417.48 Metric tons of CO2 equivalent
Purchased goods and services 11.70 Metric tons of CO2 equivalent
Capital goods ---
Fuel- and energy-related activities not included in Scope 1 or Scope 2 ---
Waste generated in operations 887.70 Metric tons of CO2 equivalent
Other categories ---

A brief description of the institution’s GHG emissions reduction initiatives, including efforts made during the previous three years:
Colorado College is committed to meeting its 2020 carbon neutrality goal. In the first four years, as directed by the Sustainability Plan drafted in 2009, Colorado College reduced carbon emissions by more than 20% and saved $1.74 million in utility costs. Utilities management at Colorado College has become an area of increased emphasis. In FY13 CC experienced continued success in decreasing energy use and costs campus-wide. Cumulative avoided costs for utilities are estimated in excess of $2.1M since the 2008 baseline. Recent and notable accomplishments include: hiring of a full-time on Campus Energy Manager; developing the Carbon Neutrality Plan through collaboration between the Office of Sustainability, Facilities Services, and the Campus Sustainability Council; increasing renewable energy purchases via wind from Colorado Springs Utilities and solar from SunShare; introducing Sofame Heat Recovery at the Central Heating Plant, the building of various solar arrays on buildings around campus including the dean's house, Synergy house, Gaylord Apartments, The Worner Center, El Pomar Center, and Cornerstone Arts Center. The Dean's house and Synergy House are now net-zero buildings. A Campus-Micro Grid is in the initial stages of execution. This project would create a campus micro grid to reduce carbon emissions by combining heat and power processes, reduce energy costs by peak shaving, and provide infrastructure to critical infrastructure to support emergency operations. Currently during a power outage, CC can operate the central plant, but does not have power to circulate water through the buildings connected to the high temperature hot water distribution system. This project would construct a 400kW combined heat and power system at the central plant. The system would run off of natural gas and provide emergency power to the Worner Center to support cooking operations and El Pomar for use as an emergency shelter. The system would achieve carbon savings and payback by operating in parallel to with the utility grid during summer peak demand periods. This would reduce demand at the central plant, also know as peak-shaving. LED lighting in Schlessman pool and also Honnen Ice Arena replace light bulbs with more energy efficient LED bulbs, reducing GHG emissions generated from coal. LED lighting has been implemented throughout campus grounds as well. Additionally, a retro-commissioning of Cornerstone Arts Center was started in the spring of 2016. The project will reduce the overall energy intensity of the building and ensure that the building is performing as efficiently as possible.

The website URL where information about the programs or initiatives is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
CC Carbon Neutrality Plan: https://www.coloradocollege.edu/offices/sustainability/campus/air-climate/ The greenhouse gas inventory includes Colorado College's main campus, the Florissant CC Cabin, and the Baca Campus at Crestone, Colorado. Properties owned by the College but managed by external entities were excluded from the inventory, because the College is not responsible for the occupancy or maintenance of utilities for the associated buildings. 2016 Energy Report: https://www.coloradocollege.edu/offices/sustainability/CC%202016%20Annual%20Energy%20Report.pdf

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.