Overall Rating | Gold - expired |
---|---|
Overall Score | 68.46 |
Liaison | Lisa Kilgore |
Submission Date | March 20, 2015 |
Executive Letter | Download |
Cornell University
OP-2: Outdoor Air Quality
Status | Score | Responsible Party |
---|---|---|
1.00 / 1.00 |
Ilene
Miller EH&S Air Compliance Officer EH&S |
"---"
indicates that no data was submitted for this field
None
Does the institution have policies and/or guidelines in place to improve outdoor air quality and minimize air pollutant emissions from mobile sources?:
Yes
None
A brief description of the policies and/or guidelines to improve outdoor air quality and minimize air pollutant emissions from mobile sources:
Cornell routinely requires (or analyzes in-house) emissions from all sources (stationary equipment, labs, etc.) and maintains strict standards regarding these emissions – exceeding regulatory requirements. Cornell also has “non-idling” requirements that reduce emissions from mobile sources, in addition to a strong commitment to low emission and no emission vehicles in the fleet and a robust Transportation Demand Management program, all of which reduce mobile emissions.
None
Has the institution completed an inventory of significant air emissions from stationary sources on campus?:
Yes
None
A brief description of the methodology(ies) the institution used to complete its air emissions inventory:
Cornell has large (twin 15-MW) co-generating gas turbines and additional boilers and equipment, and due to the size of this equipment we are required to rigorously measure and report all air emissions campus-wide as part of our Title V (Clean Air Act) permit. This inventory is used in calculating our "Scope 1" emissions for reporting to the ACUPCC and others using the standards documented in that report.
None
Weight of the following categories of air emissions from stationary sources::
Weight of Emissions | |
Nitrogen oxides (NOx) | 17.80 Tons |
Sulfur oxides (SOx) | 6.80 Tons |
Carbon monoxide (CO) | 0.95 Tons |
Particulate matter (PM) | 6.90 Tons |
Ozone (O3) | 0 Tons |
Lead (Pb) | 0 Tons |
Hazardous air pollutants (HAPs) | 0 Tons |
Ozone-depleting compounds (ODCs) | 0 Tons |
Other standard categories of air emissions identified in permits and/or regulations | 1.14 Tons |
None
A brief description of the institution’s initiatives to minimize air pollutant emissions from stationary sources, including efforts made during the previous three years:
The University uses a robust program of energy conservation, co-generation, low-emission fuels, and continuous emissions monitoring to minimize emissions to the lowest level necessary to operate the University in a reliable and efficient manner.
None
The website URL where information about the institution’s outdoor air quality policies, guidelines or inventory is available:
Data source(s) and notes about the submission:
---
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.