Overall Rating Gold - expired
Overall Score 70.05
Liaison Lisa Kilgore
Submission Date March 22, 2016
Executive Letter Download

STARS v2.0

Cornell University
OP-9: Clean and Renewable Energy

Status Score Responsible Party
Complete 0.65 / 4.00 Mark Howe
Program Manager
Energy Managment
"---" indicates that no data was submitted for this field

None
Total energy consumption (all sources, transportation fuels excluded), performance year:
3,252,197 MMBtu

None
Clean and renewable energy from the following sources::
Performance Year
Option 1: Clean and renewable electricity generated on-site during the performance year and for which the institution retains or has retired the associated environmental attributes 14,087 MMBtu
Option 2: Non-electric renewable energy generated on-site 516,702 MMBtu
Option 3: Clean and renewable electricity generated by off-site projects that the institution catalyzed and for which the institution retains or has retired the associated environmental attributes 0 MMBtu
Option 4: Purchased third-party certified RECs and similar renewable energy products (including renewable electricity purchased through a certified green power purchasing option) 0 MMBtu

None
A brief description of on-site renewable electricity generating devices :
Cornell owns and operates two hydroelectric generators. The turbine manufacturer is Ossberger and the units are rated at 712 kw and 997 kw. In addition, there are two solar photovoltaic installations of 15.0 and 2.2 kw.

None
A brief description of on-site renewable non-electric energy devices:
Cornell has installed two solar hydronic hot water systems. The systems use the solar energy to heat water in evacuated tube solar collectors. The systems are designed to offset the need for fossil fuels to provide a portion of the heating and hot water needs of two campus facilities (23 total panels with 30 tubes each). Each tube is rated at 1,000 btu/day at peak summer solar insolation. Cornell also has a heat exchange facility (Lake Source Cooling) to produce up to 20,000 peak tons of chilled water for campus. It generates renewable cooling by exchange heat to cold water from deep in Cayuga Lake saving 86% of the energy of conventional cooling (~25 million kWhr/year, about 10% of total campus electricity usage).

None
A brief description of off-site, institution-catalyzed, renewable electricity generating devices:
---

None
A brief description of the RECs and/or similar renewable energy products:
---

None
The website URL where information about the institution's renewable energy sources is available:
Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.