Overall Rating | Gold |
---|---|
Overall Score | 81.96 |
Liaison | Lindsey Lyons |
Submission Date | March 1, 2024 |
Dickinson College
OP-6: Clean and Renewable Energy
Status | Score | Responsible Party |
---|---|---|
2.31 / 4.00 |
Kenneth
Shultes AVP for Sustainability Sustainability |
"---"
indicates that no data was submitted for this field
Total energy consumption (electric and non-electric)
119,017.26
MMBtu
Clean and renewable energy sources
Clean and renewable electricity
kWh | MMBtu | |
Imported electricity from certified/verified clean and renewable sources (i.e., bundled green power purchases) | 4,608,544 Kilowatt-hours | 15,724.35 MMBtu |
Electricity from on-site, clean and renewable sources (rights retained/retired) | 340,000 Kilowatt-hours | 1,160.08 MMBtu |
A brief description of the certified/verified sources of clean and renewable electricity:
Dickinson's solar field is a 3-MW solar facility constructed on Dickinson property. Dickinson purchases electricity from the solar field through a power purchasing agreement with NextEra. http://www.dickinson.edu/news/article/3036/?utm_source=dickinsontoday&utm_medium=email&utm_campaign=dickinsontoday
(The original developer was Solar City, who sold the rights to Tesla, who then sold the rights to NextEra Energy).
(The original developer was Solar City, who sold the rights to Tesla, who then sold the rights to NextEra Energy).
A brief description of the on-site renewable electricity generating facilities/devices:
Grid-tied solar panels are installed at five locations on campus: Waidner-Spahr Library, Kaufman Hall, Center for Sustainable Living, Quarry trellis, and Britton Plaza. Additionally, most of the electricity needed for our farm operations is generated by grid-tied pv panels at the farm.
Also, in FY22, the college retained the RECS associated with the generation of 200,000 kwh from our solar field.
When combining our on-campus arrays listed above plus the energy from the solar field for which we retained RECS, the total for on-site renewable sources is 340,000 kwh.
Also, in FY22, the college retained the RECS associated with the generation of 200,000 kwh from our solar field.
When combining our on-campus arrays listed above plus the energy from the solar field for which we retained RECS, the total for on-site renewable sources is 340,000 kwh.
Clean and renewable thermal energy
MMBtu | |
Clean and renewable stationary fuels used on-site to generate thermal energy | 0 MMBtu |
Imported steam, hot water, and/or chilled water from certified/verified clean and renewable sources | 0 MMBtu |
A brief description of the clean and renewable stationary fuels:
---
A brief description of the certified/verified sources of clean and renewable thermal energy:
---
Unbundled renewable energy products
kWh | MMBtu | |
Purchased RECs, GOs, I-RECs or equivalent unbundled renewable energy products certified by a third party | 15,230,000 Kilowatt-hours | 51,964.76 MMBtu |
A brief description of the unbundled renewable energy products:
In FY22, Dickinson purchased unbundled certified wind RECs equivalent to 100% of annual electricity purchases.
Metrics used in scoring
68,849.19
MMBtu
Percentage of total energy consumption from clean and renewable sources:
57.85
Optional Fields
Sierra magazine requests the following information from U.S. institutions that wish to share data with that organization:
Percentage of total electricity use (0-100) | |
Biomass | 0 |
Coal | 0 |
Geothermal | 0 |
Hydro | 0 |
Natural gas | 0 |
Nuclear | 0 |
Solar photovoltaic | 27.50 |
Wind | 72.50 |
Other (please specify and explain below) | --- |
A brief description of other sources of electricity not specified above:
Percentages are based on 4,608 MWh/yr electricity from Dickinson's 3-MW Solar Field power purchasing agreement and 15,230 MWh of unbundled wind RECs. Together these exceed 100% of Dickinson's total annual electricity purchases.
Energy used for heating buildings, by source::
Percentage of total energy used to heat buildings (0-100) | |
Biomass | 0 |
Coal | 0 |
Electricity | 5 |
Fuel oil | 1 |
Geothermal | 0 |
Natural gas | 94 |
Other (please specify and explain below) | 0 |
A brief description of other sources of building heating not specified above:
---
Additional documentation to support the submission:
---
Data source(s) and notes about the submission:
Energy source % for grid electricity for RFCE region can be accessed at https://www.epa.gov/egrid/power-profiler#/
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.