Overall Rating | Gold - expired |
---|---|
Overall Score | 68.96 |
Liaison | Olivia Herron |
Submission Date | March 1, 2019 |
Executive Letter | Download |
Miami University
OP-4: Building Design and Construction
Status | Score | Responsible Party |
---|---|---|
1.82 / 3.00 |
Adam
Sizemore Director of Sustainability Physical Facilities Department |
"---"
indicates that no data was submitted for this field
Total floor area of newly constructed or renovated building space (include projects completed within the previous five years) :
2,317,209
Square feet
Certified Projects
0
Square feet
Floor area of newly constructed or renovated building space certified at each level under a rating system for design and construction used by an Established Green Building Council (GBC) :
Certified Floor Area | |
LEED BD+C Platinum or at the highest achievable level under another rating system | 0 Square feet |
LEED BD+C Gold or at the 2nd highest level under another 4- or 5-tier GBC rating system | 334,450 Square feet |
Certified at mid-level under a 3- or 5-tier GBC rating system for design and construction (e.g. BREEAM, CASBEE, DGNB, Green Star) | 0 Square feet |
LEED BD+C Silver or at a step above minimum level under another 4- or 5-tier GBC rating system | 1,450,855 Square feet |
LEED BD+C Certified or certified at minimum level under another GBC rating system | 0 Square feet |
Floor area of newly constructed or renovated building space certified under a non-GBC rating system for design and construction (e.g. Green Globes NC, Certified Passive House):
0
Square feet
Percentage of newly constructed or renovated building space certified under a green building rating system for design and construction:
77.05
If reporting certified projects, provide:
LEED Silver is identified as one of the certification minimum standards for new construction projects and major renovations per Miami's 2016 Sustainability Commitments and Goals (SCAG). Below is a complete list of our LEED certified (or pending) buildings as of FY2018. As of FY2018, Miami University has a total of 29 LEED-certified buildings: 27 Silver and/or Silver (pending) and 2 Gold. Miami University has three additional strategic plans that include green building design and construction guidelines and policies. These are included in PA-2: Sustainability Planning but are listed here, as well:
Miami University Stormwater Management Overlay
Western Campus Master Plan
Long Range Housing Master Plan
LEED Buildings include:
Athletic Performance Center: Silver (pending)
Garden Commons Dining: Silver
Martin Dining Hall: Silver
Western Dining Commons: Silver
Armstrong Student Center: Ph 1 Silver (pending), Ph 2 Silver
Maplestreet Station: Silver
Scott Hall: Silver (Pending)
Anderson Hall: Silver
Beechwoods Hall: Silver
Brandon Hall: Silver
Clawson Hall: Silver (Pending)
Collins Hall: Silver
Dennison Hall: Gold
Dodds Hall: Silver (Pending)
Dorsey Hall: Silver
Etheridge Hall: Silver
Flower Hall: Silver
Hahne Hall: Silver
Hamilton Hall: Gold
Hepburn Hall: Silver
Hillcrest Hall: Silver
McBride Hall: Silver
McFarland Hall: Silver
Minnich Hall: Silver (pending)
Stanton Hall: Silver (pending)
Stonebridge Hall: Silver
Symmes Hall: Silver
Farmer School of Business: Silver
Shideler Hall: Silver
MacCracken Hall, Richard Hall, and Porter Hall are currently under construction and will be LEED certified Silver.
Pearson, also under a phased construction, will be Gold when complete.
If reporting uncertified projects, provide:
Uncertified Projects
531,904
Square feet
If reporting published green building guidelines or policies, provide the following:
---
The green building guidelines or policies:
Miami's goal is to achieve LEED Silver (Version 4), 2 Green Globes, or Living Building Challenge 3.0 for all new construction and major renovation projects. Even though full certification was not sought for uncertified projects, the planning and design team followed green standards (example ENERGY STAR).
Do the green building guidelines or policies cover the following?:
Yes or No | |
Impacts on the surrounding site (e.g. guidelines to reuse previously developed land, protect environmentally sensitive areas, and otherwise minimize site impacts) | Yes |
Energy consumption (e.g. policies requiring a minimum level of energy efficiency for buildings and their systems) | Yes |
Building-level energy metering | Yes |
Use of environmentally preferable materials (e.g. guidelines to minimize the life cycle impacts associated with building materials) | Yes |
Indoor environmental quality (i.e. guidelines to protect the health and comfort of building occupants) | Yes |
Water consumption (e.g. requiring minimum standards of efficiency for indoor and outdoor water use) | Yes |
Building-level water metering | Yes |
A brief description of the green building guidelines or policies and/or a list or sample of buildings covered:
Alongside our Sustainability Commitment and Goals, Miami University also has three other strategic plans that include green building design and construction guidelines and policies. These are included in PA-2: Sustainability Planning but are listed here, as well:
Miami University Stormwater Management Overlay
Western Campus Master Plan
Long Range Housing Master Plan
In the past 5 years, the list of buildings not certified, but were built/renovated with green building standards are:
GLOS CENTER
HOYT HALL
HUGHES HALL
SHRIVER CENTER
KREGER HALL
None
A brief description of how the institution ensures compliance with green building design and construction guidelines and policies:
Each of the buildings undergoes third-party verification. The project team is responsible to ensure compliance. The project team is also responsible for ensuring compliance with as much green building standards as possible for uncertified projects.
Optional Fields
Additional documentation to support the submission:
---
Data source(s) and notes about the submission:
---
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.