Overall Rating | Platinum |
---|---|
Overall Score | 87.91 |
Liaison | Pierre Lemay |
Submission Date | Dec. 19, 2022 |
Université Laval
OP-3: Building Design and Construction
Status | Score | Responsible Party |
---|---|---|
1.25 / 3.00 |
Pierre
Lemay Development Advisor Office of the Vice Rector, External and International Affairs and Health |
"---"
indicates that no data was submitted for this field
Total floor area of newly constructed or renovated building space:
149,682.94
Square feet
Floor area of eligible building space designed and built in accordance with published green building codes, policies, and/or rating systems:
Floor area | |
Certified at the highest achievable level under a multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Platinum or Certified Living Building) | 0 Square feet |
Certified at the 2nd highest level under a 4- or 5-tier, multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Gold) | 0 Square feet |
Certified at mid-level under a 3- or 5-tier, multi-attribute GBC rating system for design and construction (e.g., BREEAM Very Good) | 0 Square feet |
Certified at a step above minimum level under ar 4- or 5-tier, multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Silver) | 0 Square feet |
Certified at minimum level under a multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Certified) | 0 Square feet |
Certified/verified at any level under a multi-attribute, non-GBC rating system for design and construction, a green building code, or a single-attribute rating system for design and construction | 0 Square feet |
Designed and built in accordance with a multi-attribute green building code, policy, guideline, or rating system, but not certified/verified | 149,682.94 Square feet |
Designed and built in accordance with a single-attribute green building code, policy, guideline, or rating system, but not certified/verified | 0 Square feet |
Total | 149,682.94 Square feet |
Percentage of newly constructed or renovated building space certified under a green building rating system for design and construction:
0
A list of new construction and major renovation projects that indicates the green building code, policy/guideline, or rating system that applies to each building:
The Design Guide, formally adopted by the university, provide the framework for all construction and renovation projects at the university. See the full version of the design guide here: https://www.si.ulaval.ca/projets-immobiliers/guide-de-conception/ more details on sustainability are given at page 199 - https://www.si.ulaval.ca/wp-content/uploads/2022/03/Guide-de-conception-20220321.pdf
To ensure compliance with all general provisions in the Design Guide and the more specific provisions in the functional and technical programs, Université Laval appoints a project manager to supervise work and follow up as needed. Université Laval uses the commissioning process for its projects. This quality assurance process is applied from design to delivery of the work. Université Laval uses ASHERAE Guideline 0.
In recent years, new constructions were:
• Centre de valorisation des données : 1250 m2
• Carré des Affaires (agrandissement pavillons La Laurentienne et Palasis-Prince) : 1156 m2
And major renovation projects were for the building DeKoninck, on about 25% of the building space: 11 500 m2
To ensure compliance with all general provisions in the Design Guide and the more specific provisions in the functional and technical programs, Université Laval appoints a project manager to supervise work and follow up as needed. Université Laval uses the commissioning process for its projects. This quality assurance process is applied from design to delivery of the work. Université Laval uses ASHERAE Guideline 0.
In recent years, new constructions were:
• Centre de valorisation des données : 1250 m2
• Carré des Affaires (agrandissement pavillons La Laurentienne et Palasis-Prince) : 1156 m2
And major renovation projects were for the building DeKoninck, on about 25% of the building space: 11 500 m2
An inventory of new construction and major renovation projects that indicates the green building code, policy/guideline, or rating system that applies to each building:
---
Optional Fields
---
Additional documentation to support the submission:
---
Data source(s) and notes about the submission:
---
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.