Overall Rating | Gold - expired |
---|---|
Overall Score | 70.52 |
Liaison | Ruairi O'Mahony |
Submission Date | Aug. 10, 2016 |
Executive Letter | Download |
University of Massachusetts Lowell
OP-4: Building Design and Construction
Status | Score | Responsible Party |
---|---|---|
![]() |
1.42 / 3.00 |
Jean
Robinson Director of Capital Projects Facilities Project Management |
Total floor area of newly constructed or renovated building space (include projects completed within the previous five years) :
Floor area of newly constructed or renovated building space certified Living under the Living Building Challenge:
Floor area of newly constructed or renovated building space certified at each level under a rating system for design and construction used by an Established Green Building Council (GBC) :
Certified Floor Area | |
LEED BD+C Platinum or at the highest achievable level under another rating system | 0 Square feet |
LEED BD+C Gold or at the 2nd highest level under another 4- or 5-tier GBC rating system | 86,288 Square feet |
Certified at mid-level under a 3- or 5-tier GBC rating system for design and construction (e.g. BREEAM, CASBEE, DGNB, Green Star) | 0 Square feet |
LEED BD+C Silver or at a step above minimum level under another 4- or 5-tier GBC rating system | 220,734 Square feet |
LEED BD+C Certified or certified at minimum level under another GBC rating system | 0 Square feet |
Floor area of newly constructed or renovated building space certified under a non-GBC rating system for design and construction (e.g. Green Globes NC, Certified Passive House):
Percentage of newly constructed or renovated building space certified under a green building rating system for design and construction:
A brief description of the green building rating system(s) used and/or a list of certified buildings and ratings:
Floor area of newly constructed or renovated building space that is NOT certified, but that was designed and constructed in accordance with published green building guidelines and policies:
A copy of the green building guidelines or policies :
The green building guidelines or policies:
Do the green building guidelines or policies cover the following?:
Yes or No | |
Impacts on the surrounding site (e.g. guidelines to reuse previously developed land, protect environmentally sensitive areas, and otherwise minimize site impacts) | Yes |
Energy consumption (e.g. policies requiring a minimum level of energy efficiency for buildings and their systems) | Yes |
Building-level energy metering | Yes |
Use of environmentally preferable materials (e.g. guidelines to minimize the life cycle impacts associated with building materials) | Yes |
Indoor environmental quality (i.e. guidelines to protect the health and comfort of building occupants) | Yes |
Water consumption (e.g. requiring minimum standards of efficiency for indoor and outdoor water use) | Yes |
Building-level water metering | Yes |
A brief description of the green building guidelines or policies and/or a list or sample of buildings covered:
A brief description of how the institution ensures compliance with green building design and construction guidelines and policies:
The website URL where information about the programs or initiatives is available:
Additional documentation to support the submission:
Data source(s) and notes about the submission:
The score for this credit is calculated based on the percentage of "total floor area of eligible building space" designed and built in accordance with formal sustainable design guidelines and/or LEED certified. Eligible building space is defined as the total floor area of all building space eligible for certification under a green building rating system. To be eligible for certification the space must meet "minimum program requirements" for new construction & major renovations, commercial interiors or core and shell. The UMass Lowell campus has grown in square feet of building space by over 35% since fiscal year 2010. This growth includes several large new construction and renovation projects as well as many smaller projects. Due to the number of small projects, it was not feasible to review each individual project to determine whether the space met the "minimum program requirements." For the purposes of STARS reporting, the total square feet constructed/renovated was therefore conservatively assumed to be "eligible" space. By assuming all of the space was eligible the resulting STARS score for this credit may be underestimated.
Notes:
• Leitch & Bourgeois were designed to meet LEED silver but will not be formally certified. Bourgeois (62,313 SF) includes 77% certified wood by Forest Stewardship Council (FSC), low VOC paints, energy efficient lighting w/ occupancy sensors, low flow fixtures, high performance glazing and building envelope, condensing boilers, heat recovery and valance units. Leitch (62,313 SF) utilizes FCS wood, low VOC paints, energy efficient lighting w/occupancy sensors, reuse of existing buildings, low flow fixtures, new flooring with high recycled content.
• Fox Hall was also constructed with LEED design features but is not certified. Fox (17,000 SF) utilizes low flow toilets and faucets, LED lighting, high efficiency kitchen equipment, low VOC materials, FSC certified wood table tops, recycled content in carpet, sustainable casework, a pulper to convert food/paper waste to compost.
• University Crossing is going through the process to be LEED certified but is not yet certified.
The following lists information about certified buildings and green building design construction features for various UMass Lowell buildings
• Sustainability Initiatives: http://www.uml.edu/docs/LeadByExample-February132013-EnergyandSustainabilityInitiatives_tcm18-149026.pdf
• Manning Business School: http://www.uml.edu/News/press-releases/2014/BusinessBldg051614.aspx
• ETIC: http://www.uml.edu/News/stories/2011-12/ETICupdate.aspx
• University Suites: http://www.uml.edu/News/press-releases/2013/UniversitySuites091813.aspx
• University Crossing: http://www.uml.edu/News/news-articles/2014/sun-uxing-opens.aspx
• HSSB: http://www.uml.edu/News/press-releases/2013/HSSB-Opening.aspx
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.