OP-5: Building Energy Consumption

Status Score Responsible Party
Complete 4.45 / 6.00 Paul Pinkston
Director of Facilities Planning and Management
Facilities
"---" indicates that no data was submitted for this field

Part 1

This credit is based on energy inputs from offsite sources and electricity produced by onsite renewables. When the institution purchases one fuel and uses it to produce heat and/or power, you should enter only what is purchased. For example, if the institution purchases natural gas to fuel a CHP system and produce steam and electricity, only the purchased natural gas should be reported.

Figures needed to determine total building energy consumption:
Performance Year Baseline Year
Grid-purchased electricity 37,372 MMBtu 40,203 MMBtu
Electricity from on-site renewables 64 MMBtu 0 MMBtu
District steam/hot water (sourced from offsite) 0 MMBtu
+ Date Revised: Sept. 11, 2018
0 MMBtu
+ Date Revised: Sept. 11, 2018
Energy from all other sources (e.g., natural gas, fuel oil, propane/LPG, district chilled water, coal/coke, biomass) 86,172 MMBtu
+ Date Revised: Sept. 11, 2018
84,661 MMBtu
+ Date Revised: Sept. 11, 2018
Total 123,608 MMBtu 124,864 MMBtu

Start and end dates of the performance year and baseline year (or 3-year periods):
Start Date End Date
Performance Year July 1, 2015 June 30, 2016
Baseline Year July 1, 2013 June 30, 2014

A brief description of when and why the building energy consumption baseline was adopted (e.g. in sustainability plans and policies or in the context of other reporting obligations):
This was the first year that data was collected in a comprehensive manner.

Gross floor area of building space:
Performance Year Baseline Year
Gross floor area of building space 185,681.14 Gross square meters 142,969.82 Gross square meters

Source-site ratio for grid-purchased electricity:
3.41

Total building energy consumption per unit of floor area:
Performance Year Baseline Year
Site energy 0.67 MMBtu per square meter 0.87 MMBtu per square meter
Source energy 1.15 MMBtu per square meter 1.55 MMBtu per square meter

Percentage reduction in total building energy consumption (source energy) per unit of floor area from baseline:
25.81

Part 2 

Degree days, performance year (base 65 °F / 18 °C):
Degree days (see help icon above)
Heating degree days 3,671.11 Degree-Days (°C)
Cooling degree days 298.33 Degree-Days (°C)

Floor area of energy intensive space, performance year:
Floor Area
Laboratory space 1,858.06 Square meters
Healthcare space 0 Square meters
Other energy intensive space

EUI-adjusted floor area, performance year:
189,397.26 Gross square meters

Building energy consumption (site energy) per unit of EUI-adjusted floor area per degree day, performance year:
50.75 Btu / GSM / Degree-Day (°C)

Optional Fields 

Documentation (e.g. spreadsheet or utility records) to support the performance year energy consumption figures reported above:
---

A brief description of the institution's initiatives to shift individual attitudes and practices in regard to energy efficiency (e.g. outreach and education efforts):
---

A brief description of energy use standards and controls employed by the institution (e.g. building temperature standards, occupancy and vacancy sensors):
The energy management system at the campus heating/cooling plant directs temperature regulation from the distribution point. Heating/cooling set points are based on occupancy hours.

A brief description of Light Emitting Diode (LED) lighting and other energy-efficient lighting strategies employed by the institution:
LED lighting is being used in track lighting and display cabinets in the University Union, Kress Events Center, Laboratory Sciences, Instructional Services, and Weidner Center for the Performing Arts. LED lighting has also been installed in some exterior path lighting as well as in the University Union's Cloud Commons dining facility.

A brief description of passive solar heating, geothermal systems, and related strategies employed by the institution:
---

A brief description of co-generation employed by the institution, e.g. combined heat and power (CHP):
---

A brief description of the institution's initiatives to replace energy-consuming appliances, equipment and systems with high efficiency alternatives (e.g. building re-commissioning or retrofit programs):
---

The website URL where information about the programs or initiatives is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.