University of Wisconsin-River Falls
SD-10: Energy Use by Type
Status | Score | Responsible Party |
---|---|---|
N/A |
Timothy
Thum Senior Engineer Facilities Mgmt. |
"---"
indicates that no data was submitted for this field
None
The percentage of total electricity use from coal.:
61.60
None
The percentage of total electricity use from wind.:
13.94
None
The percentage of total electricity use from biomass.:
0
None
The percentage of total electricity use from natural gas.:
8.20
None
The percentage of total electricity use from solar PV.:
0
None
The percentage of total electricity use from geothermal.:
0
None
The percentage of total electricity use from nuclear.:
15.60
None
The percentage of total electricity use from hydro.:
0.22
None
The percentage of total electricity use from other.:
0.44
None
Provide a brief description.:
0.44% of the total electric supply portfolio comes from bigas from landfill projects. Solar installations exist as part of the portfolio, but comprise less than 1% of all renewables and thus are not reported individually.
None
The percentage of total energy used for heating buildings from coal.:
7
None
The percentage of total energy used for heating buildings from biomass.:
0
None
The percentage of total energy used for heating buildings from electricity.:
0
None
The percentage of total energy used for heating buildings from natural gas.:
93
None
The percentage of total energy used for heating buildings from geothermal.:
0
None
The percentage of total energy used for heating buildings from fuel oil.:
0
None
The percentage of total energy used for heating buildings from other.:
0
None
Provide a brief description.:
See notes
None
If cogeneration, please explain.:
---
Data source(s) and notes about the submission:
Campus heat is provided by a central heating plant utilizing steam boilers and distribution. The steam boilers are set up to utilize both natural gas and coal, and test firings have been done with biomass pellets. State mandates required UWRF to burn a portion of coal to maintain certifications. Due to the short heating season in spring 2012, the proportion of coal burned amounted to 7% of total campus heat in 2012. UWRF heating plant manager does not intend to burn any additional coal for the 2013 heating season as certifications have been met and natural gas prices make it advantageous to use over coal at this time.
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.