Overall Rating Silver - expired
Overall Score 60.07
Liaison Mark Klapatch-Mathias
Submission Date Feb. 24, 2017
Executive Letter Download

STARS v2.1

University of Wisconsin-River Falls
OP-5: Building Energy Consumption

Status Score Responsible Party
Complete 3.69 / 6.00 Timothy Thum
Senior Engineer
Facilities Mgmt.
"---" indicates that no data was submitted for this field

Part 1

This credit is based on energy inputs from offsite sources and electricity produced by onsite renewables. When the institution purchases one fuel and uses it to produce heat and/or power, you should enter only what is purchased. For example, if the institution purchases natural gas to fuel a CHP system and produce steam and electricity, only the purchased natural gas should be reported.

Figures needed to determine total building energy consumption:
Performance Year Baseline Year
Grid-purchased electricity 50,801 MMBtu 55,040 MMBtu
Electricity from on-site renewables 0 MMBtu 0 MMBtu
District steam/hot water (sourced from offsite) 141,612 MMBtu 156,563 MMBtu
Energy from all other sources (e.g., natural gas, fuel oil, propane/LPG, district chilled water, coal/coke, biomass) 156,563 MMBtu 156,563 MMBtu
Total 348,976 MMBtu 368,166 MMBtu

Start and end dates of the performance year and baseline year (or 3-year periods):
Start Date End Date
Performance Year Jan. 1, 2016 Dec. 31, 2016
Baseline Year Jan. 1, 2005 Dec. 31, 2005

A brief description of when and why the building energy consumption baseline was adopted (e.g. in sustainability plans and policies or in the context of other reporting obligations):
The baseline was established in 2005 as part of a State Executive Order 145 for energy reduction goals.

Gross floor area of building space:
Performance Year Baseline Year
Gross floor area of building space 2,197,037 Gross square feet 1,785,527 Gross square feet

Source-site ratio for grid-purchased electricity:
3.14

Total building energy consumption per unit of floor area:
Performance Year Baseline Year
Site energy 0.16 MMBtu per square foot 0.21 MMBtu per square foot
Source energy 0.22 MMBtu per square foot 0.29 MMBtu per square foot

Percentage reduction in total building energy consumption (source energy) per unit of floor area from baseline:
23.64

Part 2 

Degree days, performance year (base 65 °F / 18 °C):
Degree days (see help icon above)
Heating degree days 5,934 Degree-Days (°F)
Cooling degree days 856 Degree-Days (°F)

Floor area of energy intensive space, performance year:
Floor Area
Laboratory space 140,399 Square feet
Healthcare space 0 Square feet
Other energy intensive space

EUI-adjusted floor area, performance year:
2,490,955 Gross square feet

Building energy consumption (site energy) per unit of EUI-adjusted floor area per degree day, performance year:
20.63 Btu / GSF / Degree-Day (°F)

Optional Fields 

Documentation (e.g. spreadsheet or utility records) to support the performance year energy consumption figures reported above:
---

A brief description of the institution's initiatives to shift individual attitudes and practices in regard to energy efficiency (e.g. outreach and education efforts):
---

A brief description of energy use standards and controls employed by the institution (e.g. building temperature standards, occupancy and vacancy sensors):
Winter occupied temperatures are controlled between 68 and 70 degrees, unoccupied temperatures are set at 65 degrees. Summer occupied temperatures are controlled between 76 and 78 degrees. Building HVAC systems are controlled on/off based on occupancy schedule for all campus buildings through the campus Energy Management Systems (EMS).

A brief description of Light Emitting Diode (LED) lighting and other energy-efficient lighting strategies employed by the institution:
LED lights were installed in Parking Lot Q. Path lights along Cascade Avenue are LED. Some LED lights were installed in the Ames Suites Residence Hall. Wyman Education Building 6 bathrooms now have LED lights LED lights are used in the Sustainability Kiosk in the University Center. University Center Atrium flood lights are now LED. University Center kitchen ceiling lights are LED. University Center convenience store walk-in cooler has LED lights. Falcon Center parking lot and path lights are LED. Ag Science 416 - replaced fluorescent lighting with 15 LED 2'x4' fixtures. Davee Library Stair - replaced fluorescent lighting with 12 LED 2'x4' fixtures with occupancy sensors. North Hall 220 - replaced fluorescent lighting with 12 LED 2'x4' fixtures with occupancy sensors. University Center Food Venues - replaced fluorescent lighting with 19 LED 2'x4' fixtures. Wyman Education Building - replaced fluorescent lighting with 70 LED 2'x2' fixtures and occupancy sensors in corridors. Replaced fluorescent lighting with 11 LED 2'x4' fixtures and occupancy sensors in stairwells.

A brief description of passive solar heating, geothermal systems, and related strategies employed by the institution:
Domestic water heating at the Research Development Institute building and Ames Residential Suites employ passive solar heating.

A brief description of co-generation employed by the institution, e.g. combined heat and power (CHP):
There is one small 30hp co-gen turbine in the Campus Heating Plant.

A brief description of the institution's initiatives to replace energy-consuming appliances, equipment and systems with high efficiency alternatives (e.g. building re-commissioning or retrofit programs):
A new AHU and new distribution duct work was installed to serve the North Hall Auditorium, including new digital controls. Work done in both the Wyman Education Building and Kleinpell Fine Arts building has been done by in-house staff to fine-tune operations. The campus is also exploring more formal opportunities with Focus on Energy which is a state program that provides incentives. Regarding energy intensive laboratory space, we have decommissioned 5 fume hoods within the last 3 years in Ag Sci. 214, 220A, 220B, 221A, 221B and added one new unit in 417 Ag Sci.

The website URL where information about the programs or initiatives is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.